P.Energy L585TF is an automatic PV modules laminator. Max dim laminates 4500x1300mm 30mm thickness.
- Touch Screen Panel in order to program the lamination cycle in very friendly way;
- 18 PID Controls guarantee 2°C of temperature variation in all the surface of aluminium plate (0.2°C is optional);
- Water Cooling Circuit and a connection for a fast cooling-down;
- A Belt System permits the integration with the loading and unloading system (optional);
The modules laminated with P.Energy L585 TF pass the spec. IEC 61215 - IEC 61646 - IEC 61730 (exposure tests, thermal, humidity-freeze, mechanical load cycling , thistad mounting surface, hail impact and high voltage isolation).
Heating System
Type of heating: electrical;
Heat up and cool down rate: ≥ 15 K/min;
Useable heating plate area approx. 4500 mm x 1300 mm;
Number of heating zones: 20;
Temperature distribution on heating plate area during heat up: < ± 2 K;
Temperature distribution within steady state: < ± 2 K;
Temperature overflow ≤ +2 K;
Useable distance between heating plate area and upper chamber: = 30 mm;
Heating plate material specification: aluminium;
Thickness: ≥ 20 mm;
Temperature range: ≤ 180°C (200°C is optional);
Temperature display.
Vacuum System
Vacuum pump: ~ 280 m³/h (nosie reduced);
Manufacturer: DVP (Italy);
Ultimate value of vacuum: <0,5 mbar;
Controlled vacuum (0 to 1000 mbar) within lower chamber;
Controlled and programmable vacuum values (0 to 1000 mbar) within upper chamber;
Ventilating of upper chamber has to be time and pressure controlled (applied preassure time: ~0,5 - 2,5min);
High definition/resolution vacuum gauge/display;
Easy maintenance and access to the pump;
Control Unit
Type: Siemens S7 manual control interface, German, Italian and English manual;
In case of breakdown emergency functions are manually provided;
Alert during operational fault (wrong temperature or pressure values as programmed);
Control unit/console positioned on the left hand side in front of the heating plate;
Manual operations are possible;
Manual operation of each single valve
External temperature display: actual temperature
Pressure display integrated in control console
Definition of pressure with switch and over time
Control of heat up and cool down function over parameter temperature (not time)
Automatic start of preselected working cycle with closing of upper chamber/shell
General Instructions and Requirements
Maintenance friendly construction design
Loading and unloading of laminator from both sides (left and right) is possible without any handicap, thus cylinders of upper chamber have to be positioned in right way
DIN-connectors (standardized) for working medium (air, electricity, oil, water)
Changable pins in the upper chamber for easy membrane changing
Easy maintenance/removal of heating plates, clutches within vacuum chamber, fixed lead-through
Wiring of thermocouples within vacuum chamber fixed
No thermal bridges from frame to heating plates/vacuum chamber
Working hour meter integrated
Documentation in English language
Water pipes to/from vacuum chamber is mounted stress relieved
All free surfaces is not horizontal to avoid things to be laid up
Noise reduction of housing
For further information contact:
This e-mail address is being protected from spambots. You need JavaScript enabled to view it